Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
medrxiv; 2020.
Preprint in English | medRxiv | ID: ppzbmed-10.1101.2020.11.17.20232827

ABSTRACT

Many healthcare facilities report SARS-CoV-2 outbreaks but transmission analysis is complicated by the high prevalence of infection and limited viral genetic diversity. The contribution of different vectors to nosocomial infection or the effectiveness of interventions is therefore currently unclear. Detailed epidemiological and viral nanopore sequence data were analysed from 574 consecutive patients with a PCR positive SARS-CoV-2 test between March 13th and March 31st, when the pandemic first impacted on a large, multisite healthcare institution in London. During this time the first major preventative interventions were introduced, including progressive community social distancing (CSD) policies leading to mandatory national lockdown, exclusion of hospital visitors, and introduction of universal surgical facemask-use by healthcare-workers (HCW). Incidence of nosocomial cases, community SARS-CoV-2 cases and infection in a cohort of 228 HCWs followed the same dynamic course, decreasing shortly after introduction of CSD measures and prior to the main hospital-based interventions. We investigated clusters involving nosocomial cases based on overlapping ward-stays during the 14-day incubation period and SARS-CoV-2 genome sequence similarity. Our method placed 63 (79%) of 80 sequenced probable and definite nosocomial cases into 14 clusters containing a median of 4 patients (min 2, max 19) No genetic support was found for the majority of epidemiological clusters (31/44, 70%) and genomics revealed multiple contemporaneous outbreaks within single epidemiological clusters. We included a measure of hospital enrichment compared to community cases to increase confidence in our clusters, which were 1-14 fold enriched. Applying genomics, we could provide a robust estimate of the incubation period for nosocomial transmission, with a median lower bound and upper bound of 6 and 9 days respectively. Six (43%) clusters spanned multiple wards, with evidence of cryptic transmission, and community-onset cases could not be identified in more than half the clusters, particularly on the elective hospital site, implicating HCW as vectors of transmission. Taken together these findings suggest that CSD had the dominant impact on reducing nosocomial transmission by reducing HCW infection.


Subject(s)
Cross Infection , Agricultural Workers' Diseases
2.
Analyst ; 145(16): 5638-5646, 2020 Aug 21.
Article in English | MEDLINE | ID: covidwho-637680

ABSTRACT

An evaluation of a rapid portable gold-nanotechnology measuring SARS-CoV-2 IgM, IgA and IgG antibody concentrations against spike 1 (S1), spike 2 (S) and nucleocapsid (N) was conducted using serum samples from 74 patients tested for SARS-CoV-2 RNA on admission to hospital, and 47 historical control patients from March 2019. 59 patients were RNA(+) and 15 were RNA(-). A serum (±) classification was derived for all three antigens and a quantitative serological profile was obtained. Serum(+) was identified in 30% (95% CI 11-48) of initially RNA(-) patients, in 36% (95% CI 17-54) of RNA(+) patients before 10 days, 77% (95% CI 67-87) between 10 and 20 days and 95% (95% CI 86-100) after 21 days. The patient-level diagnostic accuracy relative to RNA(±) after 10 days displayed 88% sensitivity (95% CI 75-95) and 75% specificity (95% CI 22-99), although specificity compared with historical controls was 100% (95%CI 91-100). This study provides robust support for further evaluation and validation of this novel technology in a clinical setting and highlights challenges inherent in assessment of serological tests for an emerging disease such as COVID-19.


Subject(s)
Antibodies, Viral/analysis , Betacoronavirus/immunology , Coronavirus Infections/diagnosis , Pneumonia, Viral/diagnosis , Serologic Tests/methods , Adult , Aged , Aged, 80 and over , Antibodies, Viral/immunology , COVID-19 , COVID-19 Testing , Clinical Laboratory Techniques , Cohort Studies , Coronavirus Infections/blood , Coronavirus Nucleocapsid Proteins , False Negative Reactions , Female , Gold/chemistry , Humans , Immunoglobulin A/analysis , Immunoglobulin A/immunology , Immunoglobulin G/analysis , Immunoglobulin G/immunology , Immunoglobulin M/analysis , Immunoglobulin M/immunology , Male , Metal Nanoparticles/chemistry , Middle Aged , Nucleocapsid Proteins/immunology , Pandemics , Phosphoproteins , Pneumonia, Viral/blood , SARS-CoV-2 , Sensitivity and Specificity , Spike Glycoprotein, Coronavirus/immunology , Young Adult
3.
medrxiv; 2020.
Preprint in English | medRxiv | ID: ppzbmed-10.1101.2020.06.02.20120345

ABSTRACT

There is a clear requirement for an accurate SARS-CoV-2 antibody test, both as a complement to existing diagnostic capabilities and for determining community seroprevalence. We therefore evaluated the performance of a variety of antibody testing technologies and their potential as diagnostic tools. A highly specific in-house ELISA was developed for the detection of anti-spike (S), -receptor binding domain (RBD) and -nucleocapsid (N) antibodies and used for the cross-comparison of ten commercial serological assays - a chemiluminescence-based platform, two ELISAs and seven colloidal gold lateral flow immunoassays (LFIAs) - on an identical panel of 110 SARS-CoV-2-positive samples and 50 pre-pandemic negatives. There was a wide variation in the performance of the different platforms, with specificity ranging from 82% to 100%, and overall sensitivity from 60.9% to 87.3%. However, the head-to-head comparison of multiple sero-diagnostic assays on identical sample sets revealed that performance is highly dependent on the time of sampling, with sensitivities of over 95% seen in several tests when assessing samples from more than 20 days post onset of symptoms. Furthermore, these analyses identified clear outlying samples that were negative in all tests, but were later shown to be from individuals with mildest disease presentation. Rigorous comparison of antibody testing platforms will inform the deployment of point-of-care technologies in healthcare settings and their use in the monitoring of SARS-CoV-2 infections.


Subject(s)
COVID-19
4.
medrxiv; 2020.
Preprint in English | medRxiv | ID: ppzbmed-10.1101.2020.04.22.20074351

ABSTRACT

There is a worldwide shortage of reagents to perform detection of SARS-2. Many clinical diagnostic laboratories rely on commercial platforms that provide integrated end-to-end solutions. While this provides established robust pipelines, there is a clear bottleneck in the supply of reagents given the current situation of extraordinary high demand. Some laboratories resort to implementing kit-free handling procedures, but many other small laboratories will not have the capacity to develop those and/or will perform manual handling of their samples. In order to provide multiple workflows for SARS-CoV-2 nucleic acid detection we compared several commercially available RNA extraction methods: QIAamp Viral RNA Mini Kit (QIAgen), the recently developed RNAdvance Blood (Beckman) and Mag-Bind Viral DNA/RNA 96 Kit (Omega Bio-tek). We also compared different 1-step RT-qPCR Master Mix brands: TaqMan Fast Virus 1-Step Master Mix (ThermoFisher Scientific), qPCRBIO Probe 1-Step Go Lo-ROX (PCR Biosystems) and Luna(R) Universal Probe One-Step RT-qPCR Kit (NEB). We used the Centre for Disease Control (CDC) recommended primers that detect two regions of the viral N gene as well as those that detect the RdRP gene region as per Public Health England (PHE) guidelines (Charite/WHO/PHE). Our data show that the RNA extraction methods provide similar results. Amongst the qPCR reagents tested, TaqMan Fast Virus 1-Step Master Mix and Luna(R) Universal Probe One-Step RT-qPCR Kit proved most sensitive. The N1 and N2 primer-probes provide a more reliable detection than the RdRP-SARSr primer-probe set, particularly in samples with low viral titres. Importantly, we have implemented a protocol using heat inactivation and demonstrate that it has minimal impact on the sensitivity of the qPCR in clinical samples - potentially making SARS-CoV-2 testing portable to settings that do not have CL-3 facilities.

SELECTION OF CITATIONS
SEARCH DETAIL